Expulsion Fuse Element
Feature :
- Dual Sensing and Dual Fuse Link
- Current Sensing
- Dual Sensing and Dual Element type of Fuse
- The tail Length is varied to suit the Dimension of different ratings
- Button Head Link
Application :
Suitable for Oil Immersed Service
Used with Single and Three Phase Pad-mounted Transformer
Design to Protect Hi-voltage Distribution System in the event of an internal transformer fault
Always used in Series with another Interrupting Devise capable of interrupting current below Fuses minimum interrupting Current
General Purpose of using Fuses is to protect Feeder and Component such as Transformer
M S Two Pole Structure : Manufactured by National
Feature :
Two Pole Structure of Beam 200 X 100 X 9 Mtr - Two Nos
Channel 100 X 50 X 3.5 Mtr - 7 Nos
Base Plates
Clamps
Nut Bolts
Bus Bar Dimensions
Earthing arrangement is being provided
Easy Accessibility and Maintenance
The Cross Arms Shall be of MS Channel
Rubber Sheet
Feature :
Square Anti-Slip Rubber mat
Fine Finish
High Strength
Durable
Best Quality
Made from high-grad Rubber Material and Advance Machinery
Feature :
Widely used in Factory Workplace and Restorent
Some House Hold Application
Available Range :
ACSR Conductor
Feature :
ACSR is a Concentric-lay-Stander-ed Conductor consisting of Single Core Wire with one or more layers of 1350 H19 Stander-ed Aluminum Wires
Steel Core Wires are Protected from Corrosion by Galvanizing Aluminum-dad alloy
Stander-ed , High , Extra and Ultra High Strength Steel are also Available
High Tensile Strength
Batter Sag Properties
Economic Design
Application :
Mainly used overhead Transmission Line and Overhead Transmission Line
Used in Application which demands Current Carrying Capacity
Thermal Overload Relay : Manufactured by C&S
Feature :
Microprocessor Technology with Self-Supervision
Two sets of Parameters
Operating Hour Meter
Definite time for under current Protection
Select able IMT trip Characteristics
Single Step Earth Fault Supervision
CB Failure Protection
Blocking of Individual Protective Elements
The Protective Function Can freely allocated to Output Relay
Rack Mounting with Self-active Shot-Circuit Mechanism
Possibility of Serial Data Exchange
Application :
Offers Reliable Protection For LV and MV Motors which may either operated via Power Contractors or via Power Circuit Breaker
Available Range :
Input Power - 5 Hp to 80 HP
Input Current - 4 Amp to 800 Amp
Relay Range - 0.63Amp to 120 Amp
Load Break Switch
Feature :
Load Break Switch 22Kv
Load Break Switch 630Amp/1250Amp , 26.3KA
Ht HRC Fuses of Suitable Ratings
The Insulation Level is 12Kv/28Kv/85Kv
Inbuilt Auxiliary Switch
In Built Earth and Fuse trip
In Built Shunt Trip Coil
Tamper Proof
Application :
Design to provide Making or Breaking of Currents
Increases the Operating Speed of the disconnected switch Blade
Allow the Safe Interruption of the arc resulting
Disconnected switch can be supplied with Equipment to provide a limited load switching capacity
MPCB : Manufactured by BCH
Feature :
- Perfect coordinate system for motor control
- Electrical life : 100000 operation
- Excellent current limiting characteristic
- Modular snap fit accessories
- Only magnetic trip version only available on request
Available Model :
- 0.1 Amp to 25 Amp Thermal and Magnetic Re-leas